Model |
DHS1003A |
DHS1253A |
DHS1503A |
DHS2003A |
DHS2503A |
DHS3003A |
Topology |
DSP
Controlled IGBT Based Static Volatage Stabilizer |
Phase Sequence |
Three
Phase to Three Phase |
Capacity |
100KVA |
125KVA |
150KVA |
200KVA |
250KVA |
300KVA |
Input |
Nominal voltage |
340-460/ 320-480/ 300-500 VAC |
Maximum Rated Input Current @ Nominal input Voltage 340V |
170 |
212 |
255 |
340 |
425 |
509 |
Maximum Rated Input Current @ Nominal input Voltage 320V |
180 |
226 |
271 |
361 |
451 |
541 |
Maximum Rated Input Current @ Nominal input Voltage 300V |
192 |
241 |
289 |
385 |
481 |
577 |
Nominal frequency |
47
- 53 Hz |
Input Circuit Breaker Rating |
200A 3P |
250A 3P |
400A 3P |
400A 3P |
630A 3P |
630A 3P |
Input Circuit Breaker Rating |
200A 3P |
250A 3P |
315A 3P |
400A 3P |
630A 3P |
630A 3P |
Input Circuit Breaker Rating |
200A 3P |
250A 3P |
315A 3P |
400A 3P |
630A 3P |
630A 3P |
Ac connection |
Terminal
block (L1in,L2in,L3in Neutral and Ground wires) provided |
Output |
Nominal voltage |
400/415/420
VAC, Settable |
Power efficiency |
Typically
over 98 % (with 20 - 100% load conditions) |
Voltage regulation |
+/-
1% |
Maximum rated output current |
144 |
180 |
217 |
289 |
361 |
433 |
Ac connection |
Terminal
block (L1in,L2in,L3in Neutral and Ground wires) provided |
Environmental |
Ambient temperature |
0°C to + 45°C, 10 to 90% RH
non-condensing |
Cooling method |
Forced
Air Cooled |
Display |
LCD Display |
4
Line LCD Display, showing I/P, O/P Voltage , load Percentage, Fault
Annunciation, Event log(optional) |
Protections |
Standards & Safety |
Designed
to meet UL 60950-1 standards. Protection class IP 20. |
OV/UV cut off with SPP |
Electronic
cut off circuit with graded time delay for High/Low/Missing Voltage |
Overload & Short Circuit Protection |
CT based electronic Cutoff circuit with
graded time delay set @110%of rated full load current |
Soft Switch-On |
This
feature ensure that output voltage is never higher than
input voltage upon switch-on, before it commences full stabilization. |
Automatic bypass |
Automatic
bypass will be activated when there is a fault condition(Optional) |
Surge Test Conditions |
Per
Class 2 Surge (combination wave) |
Surge let-through voltages |
8
X 20 µs upto 40 kA waveform. L-N < 460V |
Resetting Mode |
Manual
and Automatic Option Provided |
Physical |
Dimensions (L X W X H in mm) |
425
X 250 X 460 |
450
X 250 X 520 |
600
X 450 X 700 |
Weight (approx. in Kgs) |
184 |
250 |
335 |
365 |
365 |
420 |
Mounting |
Wheel
Mounted with Breaks |
WARRANTY |
Two
year limited warranty, covering repair/replacement of defective parts |